UniAmp Multi Channel
The UniAmp Multi Channel provides open channel configuration and a full level of user friendliness and performance. With the fx-6, fx-3, and x-5 systems, you get our most flexible solutions that meet your needs today and in future applications. Read more...
Connect all sensors
- Temperature compensation of sensor data
- E2PROM recognition of unique sensor data
- USB-powered
- fx-6 UniAmp with support for ALL Unisense microsensors
- Ease-of-use, Simple and Smart!
UniAmp Multi Channel is available with channels for amperometric sensors (O2, NO, H2, H2S, N2O), for potentiometric sensors (pH and Redox), and for optical oxygen (OPTO) sensors. All versions include one channel for a temperature sensor needed for temperature compensation of data. When you connect the sensors, they will immediately polarize.
The amplifiers are USB powered. Connect the UniAmp Multi Channel to your PC to automatically initiate the Windows service app. In the app, you can quickly review raw data and amplifier settings. You can calibrate and log data via our SensorTrace Suite apps.
Temperature compensation
Sensor temperature compensation is available for our O2, N2O, H2, and H2S microsensors. The compensation covers +/- 3°C from calibration point to ensure the quality of your data.
With a standard sensor coefficient of 2-3% per degree Celsius, small sample temperature changes from calibration point of a few degrees will result in considerable errors. With our temperature compensation algorithm, the system will compensate and ensure more accurate data.
Each sensor comes with a factory value for temperature compensation, but you can measure and apply your own value for the sensor.
OPTO channel
The fx-6 and fx-3 UniAmp Multi Channel include an optical channel for our OPTO sensors. This gives you the most flexibility, as you can choose amperometric oxygen or optical oxygen depending on your given application. With the fx-6 UniAmp, Unisense offers you the only solution available for all microsensor technologies in one unit.
E2PROM sensor connectors
The 10 pin E2PROM sensor connector can read important information about sensor type, sensor customizations, serial number, calibration data, and the unique value for individual temperature compensation. User calibration can also be stored on the E2PROM to save time during setup and provide flexibility for using multiple sensors and amplifiers. All E2PROM information is read by the UniAmp ensuring correct sensor polarization and setup. Data are transferred to our SensorTrace Suite software for enhanced user experience and experimental documentation.
The new connector format allows for support of our specialized sensors like the STOX sensor for measuring ultra-low (<5nM) oxygen.
Attribute | Standard |
---|---|
Attribute
Dimensions
|
Standard
225 x 165 x 50 mm (W x D x H)
|
Attribute
Weight
|
Standard
Approx. 1.4 kg (3.1 lbs)
|
Attribute
Temperature range
|
Standard
Operating conditions 0°C - 50°C (<90% RH non-condensing)
|
Attribute
Warranty
|
Standard
1 year
|
Attribute
Certification
|
Standard
CE
|
Picoampere | pH/mV | Optical | Temperature | Pressure | |
---|---|---|---|---|---|
Sensor
|
Picoampere
Snap connector 10 pin
|
pH/mV
Snap connector 10 pin
|
Optical
Optical ST
|
Temperature
Snap connector 4 pin
|
Pressure
Built-in
|
Reference (for mV channels)
|
Picoampere
N/A
|
pH/mV
Banana plug on the cable
|
Optical
N/A
|
Temperature
N/A
|
Pressure
N/A
|
Grounding
|
Picoampere
Banana plug
|
pH/mV
Banana plug
|
Optical
Banana plug
|
Temperature
Banana plug
|
Pressure
Banana plug
|
Polarization
|
Picoampere
Digitally adjustable
|
pH/mV
N/A
|
Optical
N/A
|
Temperature
N/A
|
Pressure
N/A
|
Polarization range
|
Picoampere
±1.8 V
|
pH/mV
N/A
|
Optical
N/A
|
Temperature
N/A
|
Pressure
N/A
|
Input range
|
Picoampere
±500 pA - 500 nA
|
pH/mV
±5000 mV
|
Optical
N/A
|
Temperature
-10 to 100°C
|
Pressure
300-1,200 mbar
|
Input impedance
|
Picoampere
N/A
|
pH/mV
>10¹³ Ohm
|
Optical
N/A
|
Temperature
N/A
|
Pressure
N/A
|
Picoampere | pH/mV | Optical | Temperature | Pressure | |
---|---|---|---|---|---|
Power supply
|
Picoampere
USB
|
pH/mV
USB
|
Optical
USB
|
Temperature
USB
|
Pressure
USB
|
Specification
|
Picoampere
5V@500 mA (Max 350 mA draw)
|
pH/mV
5V@500 mA (Max 350 mA draw)
|
Optical
5V@500 mA (Max 350 mA draw)
|
Temperature
5V@500 mA (Max 350 mA draw)
|
Pressure
5V@500 mA (Max 350 mA draw)
|
Resolution
|
Picoampere
16 bit
|
pH/mV
16 bit
|
Optical
16 bit
|
Temperature
16 bit
|
Pressure
24 bit
|
Sampling frequency
|
Picoampere
Digitally adjustable
|
pH/mV
Digitally adjustable
|
Optical
Digitally adjustable
|
Temperature
Digitally adjustable
|
Pressure
Digitally adjustable
|
- Default
|
Picoampere
1 Hz
|
pH/mV
1 Hz
|
Optical
1 Hz
|
Temperature
1 Hz
|
Pressure
0.2 Hz
|
- Maximum
|
Picoampere
20 Hz
|
pH/mV
20 Hz
|
Optical
1 Hz
|
Temperature
20 Hz
|
Pressure
0.2 Hz
|
Picoampere | pH/mV | Optical | Temperature | Pressure | |
---|---|---|---|---|---|
Response time (90%)
|
Picoampere
<35 msec.
|
pH/mV
<35 msec.
|
Optical
<1 sec.
|
Temperature
<35 msec.
|
Pressure
<5 sec.
|
Signal gain factor adjustment
|
Picoampere
0.1, 1, 10, 100
|
pH/mV
0.1, 1, 10, 100
|
Optical
0.1, 1, 10, 100
|
Temperature
0.1, 1, 10, 100
|
Pressure
0.1, 1, 10, 100
|
Signal offset adjustment
|
Picoampere
±1 V
|
pH/mV
±1 V
|
Optical
N/A
|
Temperature
N/A
|
Pressure
N/A
|
Feature | Standard |
---|---|
Feature
Digital interface
|
Standard
USB
|
Feature
Analog In
|
Standard
2 channels 0-3.3V, 16 bit ADC (optional)
|
Feature
Analog Out
|
Standard
6 Channels 0-4V scaled or unscaled
|
Feature
Digital I/O
|
Standard
5 I/O optional
|
Feature
SensorTrace Logger
|
Standard
Included
|
Feature
Other Unisense Software
|
Standard
Optional: SensorTrace Profiling
|
Feature
Data rate
|
Standard
Default 1 samples/sec.
|
Feature
Software data output
|
Standard
CSV, Excel or SQL file
|
Product | Description |
---|---|
Product
fx-6 UniAmp
|
Description
2x pA, 2x mV, 1x Temp, and 1x Opto channel
|
Product
fx-3 pA UniAmp
|
Description
1x pA, 1x Temp, and 1x Opto channel
|
Product
fx-3 mV UniAmp
|
Description
1x mV, 1x Temp, and 1x Opto channel
|
Product
x-5 UniAmp
|
Description
2x pA, 2x mV, and 1x Temp channel
|
Product
Customized fx-6 or x-5 UniAmp
|
Description
Customized channel configuration against a fee
|
Text Guides
Quick Enquiry
Related products
High performance oxygen microsensor
Microprofiles with extreme accuracy, high spatial and temporal resolution
Optical oxygen sensor technology
Detect hydrogen sulfide in your sample
Economic amplifier portfolio for single analytes - O2, pH/mV, H2, N2O or H2S
Highly sensitive hydrogen microsensor for gas and liquid measurements
Optode meter for accurate quantification
Measure dissolved and gaseous nitrous oxide
Measure minute concentrations of nitric oxide
Miniaturized pH electrode
Measure redox potential in microenvironments
Microelectrode to measure electric potential
Reference electrode for pH or Redox microelectrodes
Monitor temperature in your sample
Measure ultra low oxygen concentrations (<10nM)