Temperature Sensor
The Unisense Temperature Sensor comes in three versions; two of them are robust sensors with a tip diameter of 2 mm and the third is a delicate glass microsensor with a tip diameter of as little as 200 µm. Read more...
Temperature Sensor in three versions
Temp-UniAmp thermosensor
The Temp-UniAmp thermosensor is a PT1000 element in a robust 2 mm steel casing. It is the standard sensor used for temperature compensation in the UniAmp laboratory portfolio.
TP2000 thermosensor
The TP2000 thermosensor is a robust, mineral-insulated thermocoupler with a tip diameter of 2 mm. The thermosensor can be used for most applications where a temperature measurement is required for monitoring or temperature compensation.
Glass thermomicrosensor
The glass thermomicrosensor has a tip diameter of as little as 200 µm. It consists of a thermocoupler inside a tapered glass capillary. This sensor can be used to determine temperature microgradients in different environments, such as hot springs biofilms, compost piles, and sediments with steep temperature gradients due to volcanic activity.
Feature | Standard |
---|---|
Feature
Total length
|
Standard
50 mm
|
Feature
Diameter 20 mm from tip
|
Standard
2 mm
|
Feature
Diameter 50 mm from tip
|
Standard
2 mm
|
Feature
Shaft diameter
|
Standard
6 mm
|
Item | Standard |
---|---|
Item
Cable
|
Standard
4-wire PTFE
|
Item
Cable length
|
Standard
2 m
|
Item
Connector
|
Standard
LEMO
|
Item
In situ mini connectors
|
Standard
No
|
Attribute | Standard |
---|---|
Attribute
Type
|
Standard
PT1000
|
Attribute
Guaranteed lifetime
|
Standard
1 year
|
Attribute
Expected lifetime
|
Standard
Years
|
Attribute
Temperature range
|
Standard
-40-80°C
|
Attribute
Temperature range tip
|
Standard
-40-80°C
|
Attribute
Waterproof
|
Standard
Yes
|
Attribute
Output
|
Standard
40 µV per °C
|
Attribute
Resolution
|
Standard
<0.1°C
|
Version | Response Time (90%) |
---|---|
Version
Temp-UniAmp
|
Response Time (90%)
<3 s
|
Feature | Standard |
---|---|
Feature
Total length
|
Standard
40 mm
|
Feature
Diameter 20 mm from tip
|
Standard
2 mm
|
Feature
Shaft diameter
|
Standard
8 mm
|
Feature
Shaft protection diameter
|
Standard
11 mm
|
Item | Standard |
---|---|
Item
Cable
|
Standard
Habia
|
Item
Cable length
|
Standard
1.5-2 m
|
Item
Connector
|
Standard
LEMO
|
Item
In situ mini connectors
|
Standard
No
|
Attribute | Standard |
---|---|
Attribute
Type
|
Standard
Mineral insulated thermocouple
|
Attribute
Guaranteed lifetime
|
Standard
1 year
|
Attribute
Expected lifetime
|
Standard
Years
|
Attribute
Temperature range
|
Standard
-40-80°C
|
Attribute
Temperature range tip
|
Standard
-40-100°C
|
Attribute
Waterproof
|
Standard
Yes
|
Attribute
Output
|
Standard
40 µV per °C
|
Attribute
Resolution
|
Standard
0.1°C
|
Version | Response Time (90%) |
---|---|
Version
TP-2000
|
Response Time (90%)
<3 s
|
Feature | Standard | Options | Extra price for option selection |
---|---|---|---|
Feature
Total length
|
Standard
150-250 mm
|
Options
70-350 mm
|
Extra price for option selection
20-50%
|
Feature
Diameter 20 mm from tip
|
Standard
<2 mm
|
Options
<1 mm
|
Extra price for option selection
10%
|
Feature
Diameter 50 mm from tip
|
Standard
8 mm
|
Options
<2 mm
|
Extra price for option selection
20%
|
Feature
Shaft diameter
|
Standard
8 mm
|
||
Feature
Shaft protection diameter*
|
Standard
11 mm
|
Options
Can be omitted
|
*When mounted with in situ mini connectors, the shaft has no protection mounted, but fits directly into the in situ sensor mounts with pressure compensation. In situ sensors have a standard length of 130-160 mm.
Item | Standard | Options | Extra price for option selection |
---|---|---|---|
Item
Cable
|
Standard
Standard thermocouple cable (type T)
|
||
Item
Cable length
|
Standard
1.5-2 m
|
Options
0-5 m
|
Extra price for option selection
Yes, depends on length
|
Item
Connector
|
Standard
Standard thermocouple connector (type T)
|
||
Item
In situ mini connectors*
|
Standard
No
|
Options
Yes
|
*When mounted with in situ mini connectors, the shaft has no protection mounted, but fits directly into the in situ sensor mounts with pressure compensation. In situ sensors have a standard length of 130-160 mm.
Attribute | Standard |
---|---|
Attribute
Type
|
Standard
Thermocouple, copper / constantan (type T)
|
Attribute
Guaranteed lifetime
|
Standard
3 months
|
Attribute
Expected lifetime
|
Standard
>1 year
|
Attribute
Temperature range
|
Standard
-10-70°C
|
Attribute
Temperature range tip
|
Standard
-20-100°C
|
Attribute
Waterproof
|
Standard
Yes
|
Attribute
Spatial resolution
|
Standard
Approx. 2 times outside tip diameter
|
Attribute
Output
|
Standard
40 µV per °C
|
Attribute
Resolution
|
Standard
0.1°C
|
Version | Response Time (90%) |
---|---|
Version
Glass thermomicrosensor
|
Response Time (90%)
<3 s
|
Version | Size and description |
---|---|
Version
Temp-UniAmp
|
Size and description
2 mm - robust temperature sensor for UniAmp portfolio
|
Version
TP-2000
|
Size and description
2 mm - sensor
|
Version
TP-200
|
Size and description
180-220 µm - glass sensor
|
Version
TP-500
|
Size and description
400-600 µm - glass sensor
|
Version
TP-MR
|
Size and description
400-600 µm - in guide
|
Version
TP-N
|
Size and description
1.1 x 40 mm - needle sensor
|
Version
TP-NP
|
Size and description
1.6 x 40 mm - needle sensor for piercing
|
Version
TP-ST-1/4
|
Size and description
1/4'' steel tube
|
Version
TP-SL-1/4
|
Size and description
FT-cell 1/4'' Swagelok Tee
|
Version
TP-SL-1/8
|
Size and description
FT-cell 1/8'' Swagelok Tee
|
Version
TP-PEEK-1/8
|
Size and description
FT-cell 1/8'' PEEK Tee
|
Version
TP-PEEK-1/16
|
Size and description
FT-cell 1/16'' PEEK Tee
|
Version
TP-FT-GLASS-6
|
Size and description
Glass FT-cell 6mm outer diameter
|
Version
TP-FT-GLASS-8
|
Size and description
Glass FT-cell 8mm outer diameter
|
Text Guide
Quick Enquiry
Related products
UniAmp Multi Channel for all Unisense sensors and electrodes including optical sensors
Microprofiles with extreme accuracy, high spatial and temporal resolution
Water resistant Field MicroProfiling System to generate, study, and analyze microprofiles
Economic amplifier portfolio for single analytes - O2, pH/mV, H2, N2O or H2S