O2 UniAmp
pH Redox UniAmp
H2 UniAmp
N2O UniAmp
H2S UniAmp
UniAmp back
Single sensor channel plus temperature
Built-in temperature compensation
USB-powered
E2PROM sensor connector

UniAmp Single Channel

Economic amplifier portfolio for single analytes - O2, pH/mV, H2, N2O or H2S

With the UniAmp Single Channel, you get our most cost-effective solutions with dedicated channel configuration for O2, pH/mV, H2, N2O, and H2S. You should consider the UniAmp Multi Channel, if you need multiple sensors or a system that is more flexible for future applications. Read more...

Read More
Technical Data
Interface and Software
Ordering Information
Manuals & Videos
Quick Enquiry
UniAmp Single

Innovative amplifier solutions with unique features

  • Temperature compensation of sensor data
  • E2PROM recognition of unique sensor data
  • USB-powered
  • Cost-effective solutions for dedicated measuring needs
  • Easy-to-use, simple, and smart

UniAmp Single Channel is available in various configurations with dedicated channels for O2, pH/mV, H2, N2O, or H2S. All versions include one channel for a temperature sensor for temperature compensation of data.

The amplifier is USB powered, and the sensors immediately polarize when connected. Connect the UniAmp to your PC to automatically initiate the Windows service app. In the app, you can quickly review raw data and amplifier settings.  You can calibrate and log data via our SensorTrace Suite apps.

Temperature compensation

Sensor temperature compensation was once reserved for optical sensors. However, based on long-time in-house data temperature compensation is available for our O2, N2O, H2, and H2S microsensors.

The compensation covers +/- 3°C from calibration point, thus ensuring you better data. With a standard sensor coefficient of 2-3% per degree Celsius, small sample temperature changes from calibration point of a few degrees will result in considerable errors. With our temperature compensation algorithm, the system will compensate and ensure more accurate data.

Each sensor comes with a factory value for temperature compensation, but you can measure your own value for the sensor and apply this value.

UniAmp Temp Comp._700x400

E2PROM sensor connectors

The 10 pin E2PROM sensor connector reads important information about sensor type, sensor customizations, serial number, calibration data, and the unique value for individual temperature compensation. User calibration can also be stored on the E2PROM to save time during setup and provide flexibility for using multiple sensors and amplifiers. All E2PROM information is read by the UniAmp ensuring correct sensor polarization and setup. Data are transferred to our SensorTrace Suite software for enhanced user experience and experimental documentation.

The new connector format allows for support of our specialized sensors like the STOX sensor for measuring ultra-low (<5nM) oxygen concentrations.

Eeprom_1400x800
Characteristics
Input and Amplifier
Power and A/D Converter
Response and Signal
Characteristics
Attribute Standard
Attribute
Dimensions
Standard
225 x 165 x 50 mm (W x D x H)
Attribute
Weight
Standard
Approx. 1.4 kg (3.1 lbs)
Attribute
Temperature range
Standard
Operating conditions 0°C - 50°C (<90% RH non-condensing)
Attribute
Warranty
Standard
1 year
Attribute
Certification
Standard
CE
Input and Amplifier
Picoampere pH/mV Temperature Pressure
Sensor
Picoampere
Snap connector 10 pin
pH/mV
Snap connector 10 pin
Temperature
Snap connector 4 pin
Pressure
Built-in
Reference (for mV channels)
Picoampere
N/A
pH/mV
Banana plug on the cable
Temperature
N/A
Pressure
N/A
Grounding
Picoampere
Banana plug
pH/mV
Banana plug
Temperature
Banana plug
Pressure
Banana plug
Polarization
Picoampere
Digitally adjustable
pH/mV
N/A
Temperature
N/A
Pressure
N/A
Polarization range
Picoampere
±1.8 V
pH/mV
N/A
Temperature
N/A
Pressure
N/A
Input range
Picoampere
±500 pA - 500 nA
pH/mV
±5000 mV
Temperature
-10 to 100°C
Pressure
300-1,200 mbar
Input impedance
Picoampere
N/A
pH/mV
>10¹³ Ohm
Temperature
N/A
Pressure
N/A
Power and A/D Converter
Picoampere pH/mV Temperature Pressure
Power supply
Picoampere
USB
pH/mV
USB
Temperature
USB
Pressure
USB
Specification
Picoampere
5V@500 mA (Max 350 mA draw)
pH/mV
5V@500 mA (Max 350 mA draw)
Temperature
5V@500 mA (Max 350 mA draw)
Pressure
5V@500 mA (Max 350 mA draw)
Resolution
Picoampere
16 bit
pH/mV
16 bit
Temperature
16 bit
Pressure
24 bit
Sampling frequency
Picoampere
Digitally adjustable
pH/mV
Digitally adjustable
Temperature
Digitally adjustable
Pressure
Digitally adjustable
- Default
Picoampere
1 Hz
pH/mV
1 Hz
Temperature
1 Hz
Pressure
0.2 Hz
- Maximum
Picoampere
20 Hz
pH/mV
20 Hz
Temperature
20 Hz
Pressure
0.2 Hz
Response and Signal
Picoampere pH/mV Temperature Pressure
Response time (90%)
Picoampere
<35 msec.
pH/mV
<35 msec.
Temperature
<35 msec.
Pressure
<5 sec.
Signal gain factor adjustment
Picoampere
0.1, 1, 10, 100
pH/mV
0.1, 1, 10, 100
Temperature
0.1, 1, 10, 100
Pressure
0.1, 1, 10, 100
Signal offset adjustment
Picoampere
±1 V
pH/mV
±1 V
Temperature
N/A
Pressure
N/A
Interface and Software
Interface and Software
Feature Standard
Feature
Digital interface
Standard
USB
Feature
Analog In
Standard
2 channels 0-3.3V, 16 bit ADC (optional)
Feature
Analog Out
Standard
6 Channels 0-4V scaled or unscaled
Feature
Digital I/O
Standard
5 I/O optional
Feature
SensorTrace Logger
Standard
Included
Feature
Other Unisense Software
Standard
Optional: SensorTrace Profiling
Feature
Data rate
Standard
Default 1 samples/sec.
Feature
Software data output
Standard
CSV, Excel or SQL file
Ordering information
Ordering information
Product Description
Product
O2 UniAmp
Description
1x pA for Oxygen, 1x Temp channel
Product
pH/Redox UniAmp
Description
1x mV for pH and Redox, 1x Temp channel
Product
H2 UniAmp
Description
1x pA for Hydrogen, 1x Temp channel
Product
N2O UniAmp
Description
1x pA for Nitrous Oxide, 1x Temp channel
Product
H2S UniAmp
Description
1x pA for Sulfide (H2S and SULF), 1x Temp channel

Quick Enquiry

    If you complete the form below, we will send you a quote as soon as possible to give you a quick price indication.

    Which sensor(s) are you interested in?

    Do you have a Unisense amplifier?

    Are you interested in one of our lab systems?

    Are you interested in one of our field systems?

    We will use your e-mail for our newsletter. That's it.
    You can unsubscribe at any time.